<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Pilot solutions Archives - Primozone</title>
	<atom:link href="https://www.primozone.com/project_category/pilot-solutions/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.primozone.com/project_category/pilot-solutions/</link>
	<description>Redefining ozone technology</description>
	<lastBuildDate>Mon, 01 Dec 2025 11:22:04 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://www.primozone.com/wp-content/uploads/2025/05/cropped-Primozone_favicon_02-32x32.png</url>
	<title>Pilot solutions Archives - Primozone</title>
	<link>https://www.primozone.com/project_category/pilot-solutions/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Ozone Installations for Removal of Pharmaceutical Residue</title>
		<link>https://www.primozone.com/project/ozone-treatment-pharmaceutical-residues/</link>
		
		<dc:creator><![CDATA[amicestudio]]></dc:creator>
		<pubDate>Fri, 17 Oct 2025 07:55:55 +0000</pubDate>
				<guid isPermaLink="false">https://www.primozone.com/?post_type=project&#038;p=3659</guid>

					<description><![CDATA[<p>The post <a href="https://www.primozone.com/project/ozone-treatment-pharmaceutical-residues/">Ozone Installations for Removal of Pharmaceutical Residue</a> appeared first on <a href="https://www.primozone.com">Primozone</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="et_pb_section et_pb_section_0 et_animated et_pb_section_video et_pb_preload et_pb_with_background et_section_regular" >
				
				
				<span class="et_pb_section_video_bg   et_pb_allow_player_pause">
					
			<video loop="loop" autoplay playsinline muted >
				<source type="video/mp4" src="https://www.primozone.com/wp-content/uploads/2025/10/Primozone_ozone-technology.mp4" />
				
			</video>
				</span>
				
				
				
				<div class="et_pb_row et_pb_row_0 et_animated et_pb_gutters1">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_post_title et_pb_post_title_0 et_animated et_pb_bg_layout_light  et_pb_text_align_left"   >
				
				
				
				
				
				<div class="et_pb_title_container">
					<h1 class="entry-title">Ozone Installations for Removal of Pharmaceutical Residue</h1>
				</div>
				
			</div><div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p data-start="410" data-end="996"></p>
<blockquote data-start="2177" data-end="2285">
<p data-start="2179" data-end="2285"></p>
</blockquote></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_1 et_animated  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_dark">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Objective</h3>
<p><span>To demonstrate that ozone treatment is a reliable and cost-efficient solution for removing pharmaceutical residues and other micropollutants from municipal wastewater under various treatment conditions.</span></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_2  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Primozone solution</h3></div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_0  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">$</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Primozone Container Module</span></h4>
						
					</div>
				</div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div><div class="et_pb_section et_pb_section_1 et_animated et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_1 et_animated et_pb_gutters1">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_2  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_3  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3 data-start="1003" data-end="1048"><strong data-start="1007" data-end="1048">10 pilot installations was run in Sweden during 2014-2015</strong></h3>
<p><span>At the beginning of 2014 Primozone received funding to build a mobile pilot scale ozone system for removal of a specific kind of micropollutants i.e. pharmaceutical residue. Ozone has already been proven as one of the most efficient techniques for removal of pharmaceutical residue. The aim of these installations was to be able to prove the concept existing waste water treatment plants and to test and confirm the system design waste water treatment plants with different process conditions and treatment methods as well as different population structure.</span><br /><br /><strong data-start="1007" data-end="1048"></strong></p>
<h3 data-start="1003" data-end="1048"><strong data-start="1007" data-end="1048">Pharmaceutical Residues in Wastewater</strong></h3>
<p data-start="1050" data-end="1424">Numerous studies have established that our wastewater contains micropollutants. Of emerging concern are PPCPs (Pharmaceuticals and Personal Care Products). Many studies have also been conducted on the impact of these micropollutants on the environment. So far, limited actions have been taken to remove these residues, but political initiatives are starting to show results.</p>
<p data-start="1426" data-end="1750">Sweden is at the forefront of research on how to reduce pharmaceutical residues in wastewater. Several wastewater treatment plants have identified the problem, and many Swedish universities are studying the environmental effects of these residues. Swedish governmental bodies are also providing funding for further research.</p>
<p data-start="1752" data-end="1897">Primozone believes that it is time to take action and start removing micropollutants, including pharmaceutical residues, from our wastewater now.</p>
<p data-start="1899" data-end="2093">Current wastewater treatment plants are not equipped to remove pharmaceutical residues. However, proven technologies are readily available, and the additional cost to the water bill is very low.</p>
<p data-start="2250" data-end="2535"></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_4  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3 data-start="1003" data-end="1048"></h3>
<h3 data-start="2100" data-end="2159"><strong data-start="2104" data-end="2159">Project Implementation – Removal of Micropollutants</strong></h3>
<p data-start="2161" data-end="2248">Installation<br data-start="2177" data-end="2180" />The installation of the complete system takes approximately one day.</p>
<p data-start="2250" data-end="2535">Sampling<br data-start="2262" data-end="2265" />After the system has been operating for about two weeks, it is time to collect samples for analysis.<br data-start="2365" data-end="2368" />Samples are taken before pre-filtration, after pre-filtration, and after ozone treatment. If an additional sand filter is used, samples are also taken after that step.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_5  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><span>ing agent, breaks down complex organic compounds and significantly reduces micropollutant concentrations.</span></p></div>
			</div><div class="et_pb_module et_pb_image et_pb_image_0">
				
				
				
				
				<span class="et_pb_image_wrap "><img fetchpriority="high" decoding="async" width="999" height="620" src="https://www.primozone.com/wp-content/uploads/2025/10/removal_ppcps_primozone_pid.png" alt="" title="removal_ppcps_primozone_pid" srcset="https://www.primozone.com/wp-content/uploads/2025/10/removal_ppcps_primozone_pid.png 999w, https://www.primozone.com/wp-content/uploads/2025/10/removal_ppcps_primozone_pid-980x608.png 980w, https://www.primozone.com/wp-content/uploads/2025/10/removal_ppcps_primozone_pid-480x298.png 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 999px, 100vw" class="wp-image-3664" /></span>
			</div><div class="et_pb_module et_pb_text et_pb_text_6  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2></h2>
<h3 data-start="2100" data-end="2159"><strong data-start="2104" data-end="2159">Analysis</strong></h3>
<p> <span>The samples will the be analyzed for the following substances</span></p>
<h3 data-start="1003" data-end="1048"></h3>
<table id="tablepress-2" class="tablepress tablepress-id-2">
<thead>
<tr class="row-1">
<th class="column-1"><span style="color: #003d78;">Substance</span></th>
<th class="column-2"><span style="color: #003d78;">Mode of action</span></th>
</tr>
</thead>
<tbody>
<tr class="row-2">
<td class="column-1">Amlodipine</td>
<td class="column-2">Antihypertensives</td>
</tr>
<tr class="row-3">
<td class="column-1">Atenolol</td>
<td class="column-2">Antihypertensives</td>
</tr>
<tr class="row-4">
<td class="column-1">Bisoprolol</td>
<td class="column-2">Antihypertensives</td>
</tr>
<tr class="row-5">
<td class="column-1">Caffeine</td>
<td class="column-2">Stimulants</td>
</tr>
<tr class="row-6">
<td class="column-1">Carbamazepine</td>
<td class="column-2">Sedatives</td>
</tr>
<tr class="row-7">
<td class="column-1">Ciprofloxacin</td>
<td class="column-2">Antibiotics</td>
</tr>
<tr class="row-8">
<td class="column-1">Citalopram</td>
<td class="column-2">Antidepressants</td>
</tr>
<tr class="row-9">
<td class="column-1">Diclofenac</td>
<td class="column-2">Anti-inflammatories</td>
</tr>
<tr class="row-10">
<td class="column-1">Furosemide</td>
<td class="column-2">Diuretics</td>
</tr>
<tr class="row-11">
<td class="column-1">Hydrochlorothiazide</td>
<td class="column-2">Antihypertensives</td>
</tr>
<tr class="row-12">
<td class="column-1">Ibuprofen</td>
<td class="column-2">Anti-inflammatories</td>
</tr>
<tr class="row-13">
<td class="column-1">Ketoprofen</td>
<td class="column-2">Anti-inflammatories</td>
</tr>
<tr class="row-14">
<td class="column-1">Metoprolol</td>
<td class="column-2">Antihypertensives</td>
</tr>
<tr class="row-15">
<td class="column-1">Naproxen</td>
<td class="column-2">Anti-inflammatories</td>
</tr>
<tr class="row-16">
<td class="column-1">Oxazepam</td>
<td class="column-2">Sedatives</td>
</tr>
<tr class="row-17">
<td class="column-1">Paracetamol</td>
<td class="column-2">Anti-inflammatories</td>
</tr>
<tr class="row-18">
<td class="column-1">Propranolol</td>
<td class="column-2">Antihypertensives</td>
</tr>
<tr class="row-19">
<td class="column-1">Ranitidine</td>
<td class="column-2">Antiulcers</td>
</tr>
<tr class="row-20">
<td class="column-1">Sertraline</td>
<td class="column-2">Antidepressants</td>
</tr>
<tr class="row-21">
<td class="column-1">Sulfamethoxazole</td>
<td class="column-2">Antibiotics</td>
</tr>
<tr class="row-22">
<td class="column-1">Terbutaline</td>
<td class="column-2">Asthma medication</td>
</tr>
<tr class="row-23">
<td class="column-1">Tetracycline</td>
<td class="column-2">Antibiotics</td>
</tr>
<tr class="row-24">
<td class="column-1">Trimetoprim</td>
<td class="column-2">Antibiotics</td>
</tr>
<tr class="row-25">
<td class="column-1">Warfarin</td>
<td class="column-2">Anticoagulants</td>
</tr>
</tbody>
</table></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_3 et_animated  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_7  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Results</h3></div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_1  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">Z</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Significant reduction of pharmaceutical compounds after ozone treatment</span></h4>
						
					</div>
				</div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_2  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">Z</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Reliable performance under varying treatment conditions</span></h4>
						
					</div>
				</div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_3  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">Z</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Easy system integration with existing wastewater plants</span></h4>
						
					</div>
				</div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_4  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					
					<div class="et_pb_blurb_container">
						
						
					</div>
				</div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_2 et_animated et_pb_equal_columns et_pb_gutters1">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_4  et_pb_css_mix_blend_mode_passthrough et_pb_column_empty">
				
				
				
				
				
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_5 et_animated  et_pb_css_mix_blend_mode_passthrough et-last-child et_pb_column_empty">
				
				
				
				
				
			</div>
				
				
				
				
			</div>
				
				
			</div>
<p>The post <a href="https://www.primozone.com/project/ozone-treatment-pharmaceutical-residues/">Ozone Installations for Removal of Pharmaceutical Residue</a> appeared first on <a href="https://www.primozone.com">Primozone</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Micropollutant removal with ozone, Birmensdorf</title>
		<link>https://www.primozone.com/project/birmensdorf-ozone-wastewater-treatment/</link>
		
		<dc:creator><![CDATA[amicestudio]]></dc:creator>
		<pubDate>Tue, 14 Oct 2025 05:37:04 +0000</pubDate>
				<guid isPermaLink="false">https://www.primozone.com/?post_type=project&#038;p=2213</guid>

					<description><![CDATA[<p>The post <a href="https://www.primozone.com/project/birmensdorf-ozone-wastewater-treatment/">Micropollutant removal with ozone, Birmensdorf</a> appeared first on <a href="https://www.primozone.com">Primozone</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div class="et_pb_section et_pb_section_2 et_animated et_pb_section_video et_pb_preload et_pb_with_background et_section_regular" >
				
				
				<span class="et_pb_section_video_bg   et_pb_allow_player_pause">
					
			<video loop="loop" autoplay playsinline muted >
				<source type="video/mp4" src="https://www.primozone.com/wp-content/uploads/2025/10/Primozone_ozone-technology.mp4" />
				
			</video>
				</span>
				
				
				
				<div class="et_pb_row et_pb_row_3 et_animated et_pb_gutters1">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_6  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_post_title et_pb_post_title_1 et_animated et_pb_bg_layout_light  et_pb_text_align_left"   >
				
				
				
				
				
				<div class="et_pb_title_container">
					<h1 class="entry-title">Micropollutant removal with ozone, Birmensdorf</h1>
				</div>
				
			</div><div class="et_pb_module et_pb_text et_pb_text_8  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>The Birmensdorf Wastewater Treatment Plant, located in Switzerland, has been in operation since July 1973. It serves several municipalities, including Aesch, Birmensdorf, Bonstetten, Stallikon, Uitikon, Wettswil, and parts of Aeugstertal. As part of a long-term development plan extending to the year 2035, the plant underwent a significant expansion between 2013 and 2018. This upgrade increased its treatment capacity to serve up to 33,000 population equivalents.</p>
<p>In response to the revised water protection legislation in Switzerland, the Birmensdorf facility has recently been modernized with an advanced treatment stage specifically designed to remove micropollutants from wastewater. These substances, which include trace pharmaceuticals and personal care products, are increasingly recognized as environmental contaminants that conventional treatment methods cannot fully eliminate.</p>
<p><span>To meet these new requirements, the plant implemented ozone treatment—a proven and efficient method for advanced wastewater purification. Ozone, a powerful oxidizing agent, breaks down complex organic compounds and significantly reduces micropollutant concentrations.</span></p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_7 et_animated  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_9  et_pb_text_align_left et_pb_bg_layout_dark">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Objective</h3>
<p><span>Reduce micropollutants in wastewater through ozonation and contribute to a safe and healthy environment for operators working on site.</span><span></span></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_10  et_pb_text_align_left et_pb_bg_layout_dark">
				
				
				
				
				<div class="et_pb_text_inner"><p><span><span class="OYPEnA font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none">“Together with Rheno AG, Primozone supply, install and commission ozone systems in a easy and safe way.”<br /></span><em><span class="OYPEnA font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none">—Linus Nielsen<br /></span><span class="OYPEnA font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none">Project Manager at Primozone.</span></em></span></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_11  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Primozone solution</h3></div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_5  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">$</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>2 x GM36 ozone generators</span></h4>
						
					</div>
				</div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_6  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">$</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Filter package, destructor, backflow protectors, cooling, valves, distribution models, safety products to make a complete and reliable system.</span></h4>
						
					</div>
				</div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_7  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">$</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Joined start up with experts from Primozone together with the application experts at Rheno.</span></h4>
						
					</div>
				</div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div><div class="et_pb_section et_pb_section_3 et_animated et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_4 et_animated et_pb_gutters1">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_8  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_12  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>At Birmensdorf, the ozone system was designed to treat a continuous wastewater flow of 464 liters per second. For this purpose, two ozone generators (model GM36) were installed, with a total ozone production capacity of 4.4 kilograms of ozone per hour. The ozone is evenly distributed into the water through high-performance ceramic diffusers, ensuring maximum contact and effective treatment.</p>
<p>The project was carried out by Rheno AG, which managed the detailed engineering, equipment delivery, installation, and commissioning of the ozone stage. This upgrade not only enhances the plant’s treatment performance but also ensures compliance with stricter environmental standards and contributes to long-term water protection in the region</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_9 et_animated  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_13  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Results</h3></div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_8  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">Z</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Ozone system running and used in the process according to demands and expectations.</span></h4>
						
					</div>
				</div>
			</div><div class="et_pb_module et_pb_blurb et_pb_blurb_9  et_pb_text_align_left  et_pb_blurb_position_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon">Z</span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Improved treatment efficiency and compliance with Swiss water protection standards achieved through advanced ozone technology.</span></h4>
						
					</div>
				</div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_5 et_animated et_pb_equal_columns et_pb_gutters1">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_10  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_14  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>WWTP Birmensdorf</h3>
<p class="cvGsUA direction-ltr align-start para-style-body"><span class="OYPEnA font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none"><span>“The compact and modular design of the Primozone reactors combine a small footprint, excellent operational safety and flexibility. Rheno professionally instructed the WWTP operators to understand and handle the new technology.”<br /></span></span><em><span class="OYPEnA font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none">—Damian Hausherr</span></em></p></div>
			</div><div class="et_pb_module et_pb_image et_pb_image_1 et_animated et-waypoint et_pb_image_sticky">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="833" height="527" src="https://www.primozone.com/wp-content/uploads/2025/09/Primozone-case_Birmensdorf.png" alt="" title="" srcset="https://www.primozone.com/wp-content/uploads/2025/09/Primozone-case_Birmensdorf.png 833w, https://www.primozone.com/wp-content/uploads/2025/09/Primozone-case_Birmensdorf-480x304.png 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 833px, 100vw" class="wp-image-2936" /></span>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_11 et_animated  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_with_border et_pb_module et_pb_blurb et_pb_blurb_10 et_animated  et_pb_text_align_center  et_pb_blurb_position_top et_pb_bg_layout_dark">
				
				
				
				
				<div class="et_pb_blurb_content">
					<div class="et_pb_main_blurb_image"><span class="et_pb_image_wrap"><span class="et-waypoint et_pb_animation_top et_pb_animation_top_tablet et_pb_animation_top_phone et-pb-icon"></span></span></div>
					<div class="et_pb_blurb_container">
						<h4 class="et_pb_module_header"><span>Download PDF</span></h4>
						<div class="et_pb_blurb_description"><p><a href="https://www.primozone.com/wp-content/uploads/2025/12/Waste-water-treatment-ARA-Birmensdorf-2025.pdf">Case Story &#8211; ARA Birmensdorf</a></p></div>
					</div>
				</div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div></p>
<p>The post <a href="https://www.primozone.com/project/birmensdorf-ozone-wastewater-treatment/">Micropollutant removal with ozone, Birmensdorf</a> appeared first on <a href="https://www.primozone.com">Primozone</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
